Can a heat pump handle the cold here
Winter here is long and it gets genuinely cold. The heat runs eight months a year, October through May, and overnight lows average 16°F across December, January and February. About 150 nights a year dip to freezing or below, more than half the nights the heat is even running. Seven nights a year hit 0°F.
A standard heat pump starts losing ground before it gets that cold. Below 40°F it puts out less heat than its rating says. Below about 35°F it often needs backup heat to make up the difference. Here, the average winter night is already past both marks, and every single night at or below freezing is too. That is not a few rough nights a year. That is most of the winter.
This is why a heat pump in this county needs backup heat, and why the kind of heat pump matters. The federal minimum unit is not built for 16°F nights. A cold-climate model, the kind carrying the ENERGY STAR Cold Climate mark, is tested to hold at least 1.75 units of heat per unit of electricity at 5°F and keep 70 percent of its warm-weather capacity at that temperature. Field tests of cold-climate models in occupied homes back this up: backup heat covered only a small share of the load between 0°F and 35°F, and running on backup alone was rare even above 0°F. A furnace, gas or oil, does not lose capacity when it gets cold outside. It is built to run flat out on the coldest night of the year the same as a mild one, which is what 150 nights below freezing calls for.