What the cold actually does here
Winters in Cheshire County are long and the cold is real. Heat runs nine months a year, September through May. The overnight low averages 15°F across December, January and February, and about 170 nights a year dip to freezing or below. That's over half the nights in the whole heating season.
A standard heat pump starts losing ground before it even gets near that average. Below 40°F its output falls short of what it's rated for. Below about 35°F it often needs backup heat to keep up. Fifteen here is below both marks, and every single one of those 170 freezing nights is too. That's not an edge case for this county, it's most of the winter.
A furnace doesn't have that problem. It burns fuel and makes heat, and the cold outside doesn't change how much it makes. On the 15 nights a year that hit 0°F, that difference matters most, and it's also when a standard heat pump leans hardest on backup heat to make up the gap.
None of this rules out a heat pump. A model built for cold climates has to prove, under third-party testing, that it still makes at least 1.75 units of heat per unit of electricity at 5°F and holds onto 70 percent of its 47°F capacity at that temperature. In a two-winter field test of those cold-climate machines in real homes, backup heat only covered a small share of the load between 0°F and 35°F, and running on backup alone was rare even above 0°F. The federal-minimum heat pump in the cost comparison above isn't that machine. If you're seriously considering a heat pump here, which one it is changes the answer.