What winter here does to a heat pump
Heat here runs eight months, October through May, and the overnight low over those months averages 16°F. That one number is the whole question with a heat pump. A standard heat pump starts losing ground below 40°F and often needs backup heat below about 35°F. Here, the average winter night is below both marks, and so is every single one of the roughly 150 nights a year that drop to freezing or colder.
That does not mean a heat pump quits. A cold climate model, the ones carrying the ENERGY STAR Cold Climate mark, has to prove it can still make 1.75 units of heat per unit of electricity at 5°F and hold on to 70 percent of its warm-weather capacity at that temperature, tested by someone other than the people selling it. Field tests of cold climate heat pumps back that up: over two winters in occupied homes, backup heat covered only a small share of the load between 0°F and 35°F, and the home running on backup alone was rare even above 0°F. Hillsborough County only sees 0°F or below on about 8 nights a year. A cold climate heat pump sized and installed for this county is built for the other 150.
A standard heat pump, the kind built to the federal minimum, is a different case. That 16°F average low sits well inside the range where it is leaning on backup heat, and that backup is usually electric resistance, the most expensive way to make heat there is. The running cost printed above for the heat pump, $3.12 per 100,000 Btu, does not include a single hour of that backup. On the coldest nights here, a standard heat pump likely costs more to run than that number says.